kept in mind
- The plinth of the store shold be about 450mm above from the NGL.
- The cement bags should be placed on the wooden planks 200mm above the plinth.
- The store should be air tight.
- The stack of cement should be coverd with Polythene.
- FIFO system of inventory should be followed.